Flow Control Valve
Pressure Reducing Valve
4MATIC Pilot Operated Pressure Reducing Valve is designed for applications where the reduction of high inlet pressures to a safe and stable outlet pressure is required. The pilot assembly reacts to changes in downstream pressure allowing the main valve to modulate between the closed and open position ensuring a constant downstream set pressure. Once the downstream pressure reaches the pilot setting, the main valve will seal shut preventing damage downstream. Pressure regulation is not dependent upon flow rate, resulting in minimal pressure loss through the valve.
Pressure Relief Valve/PSV- Pressure Sustaining Valve
“4MATIC” Pressure Relief Valve is a pilot operated valve, designed specifically to relieve excess pressure. Pressure Relief Valve is designed to maintain constant upstream pressure within close limits. In operation, the valve is actuated by line pressure through a pilot control system, opening fast to maintain steady line pressure but closing gradually to prevent surges. The pressure-sustaining valves keeps constant pressure in a line regardless of variations in inlet pressure. If the inlet pressure increases for any reason the sustaining valve keeps the outlet pressure constant and reduces hammering in the pipe line.
On/ Off Type Pressure Reducing Valve
“4Matic” Solenoid Control on/off type Pressure Reducing Valve is designed to provide on/off or open/close with reduction of high inlet pressures to a safe and stable outlet pressure is required. The pilot assembly reacts to changes in downstream pressure allowing the main valve to modulate between the closed and open position ensuring a constant downstream set pressure. This valve can be control with a PLC Panel and is mostly used in application where remote on/off of pressure reducing valve is required.
Hand Lever Operated Ball Valve
“4MATIC” Ball Valve Operated Control Valve is a Globe Design Pilot Operated Diaphragm Actuated Valve. A Ball Valve acts As a Pilot designed specifically for applications where Quick Response of valve function is preferred. They function as an On/Off valve and as they are pilot operated they Open and Close in Seconds. It requires less man power and time to operate.
Solenoid Valve
“4MATIC” Solenoid Control Valve is Globe Design Pilot Operated Diaphragm Actuated Valve. Solenoid Valve as in Pilot are designed specifically for applications where remote control of valve function is preferred. They function as an On/Off valve and as they are pilot operated there Open and Close in Seconds. This Valve Helps the User to Open/Close the valve with Electric Current.
Actuator Operated Ball Valve
“4MATIC” Pneumatic Actuator Operated Hydraulic Control Valve is Globe Design Pilot Operated Diaphragm Actuated Valve. Pneumatic Ball Valve as in Pilot are designed specifically for applications where remote control of valve function is preferred. They function as an On/Off valve and as they are pilot operated there Open and Close in Seconds. More Accessories can be mounted like Limit Switch for On/Off Indication.
Y Type Control Valve
“4MATIC”Automatic Control Valve is Globe Design Pilot Operated Diaphragm Actuated Valve. A Y-Type Control as in Pilot are designed specifically for applications where there is a requirement for the valve to open when air is supplied and close when air fails. This valve works as Air to open and Air Fail to Close.
Smart Float Valve
Float Valve
“4MATIC” Float Control Valve is a Globe Design Pilot Operated Diaphragm Actuated Valve. It is installed at the inlet of the tank/reservoir, it allows to keep a constant/ set level of water. As the Float is linked to the Pilot it ensures to stop the flow of water at predetermined Level while realizes water supplement when the float lowers. This Valve helps to keep a Constant level of water in the Tank. This valve can work in a remote location, perfect for all those applications where the water tank is not easily accessible.
Level Control Valve / Modulating Float Valve
“4MATIC” Level Control Float Valve is a Globe Design Pilot Operated Diaphragm Actuated Valve. It is installed at the inlet of tank/reservoir, unlike a float valve it allows you to adjust the level of water as desired. As the Level Float is linked to the Pilot it ensures to Stop the Water Filling at predetermined Level while realizes water supplement when the float lowers to the desired level. This Valve helps to keep the optimal Water level in the Tank. The valve can work in remote location and does not require any Power Supply, so it is perfect for all those applications where the water tank is not easily accessible.
Dual Solenoid Operated Flow Control Valve
Dual Solenoid operated Flow Control Valve is used for applications where reduction in flow is required. In this valve two solenoid valves are used as pilot valves to control Flow and Pressure of the main valve. When pulse is given to the solenoid valve at the inlet, the main valve will close because the upper chamber will get filled with water and will close the diaphragm. The tension on the spring will close the main valve. When pulse given to the solenoid valve at the outlet, the main valve will gradually open, as the pressure in the upper chamber of main valve is released and the media can flow out from the main valve.
Electric Actuator Operated Pressure Reducing Valve
“4MATIC” Electric Actuator Automatic Control Valve is Globe Design Pilot Operated Diaphragm Actuated Valve. Electric Actuator Operated Pressure Reducing Valve Design in a Way where user can adjust the pressure with the Help of PLC panel. In this Valve the Pilot is Electrical Actuator Combined with Pressure Reducing Valve. Electric Actuator Controls the Pressure Reducing Valve and Pressure Reducing Valve Controls the Line Pressure and Adjust the Pressure as Desired.
Performance Specifications
SIZE | PORT A | L | OD | b | f | OG | OJ | N | PCD | weight | |||||||
mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | mm inch | kg lbs | ||
50 | 2 | 50 | 2 | 214.5 | 8.58 | 150 | 6.00 | 14.3 | 0.57 | 2 | 92.1 | 3.68 | 19.05 | 0.76 | 4 | 120.7 4.83 | 16 35 |
65 | 2.5 | 64 | 2.5 | 237.5 | 9.50 | 180 | 7.20 | 15.9 | 0.64 | 2 | 104.8 | 4.19 | 19.05 | 0.76 | 4 | 139.7 5.59 | 23 50 |
80 | 3 | 78 | 3 | 249 | 9.96 | 190 | 7.60 | 17.5 | 0.70 | 2 | 127 | 5.08 | 19.05 | 0.76 | 8 | 152.4 6.10 | 32 70 |
100 | 4 | 99.5 | 4 | 291 | 11.64 | 230 | 9.20 | 22.3 | 0.89 | 2 | 157.2 | 6.29 | 19.05 | 0.76 | 8 | 190.5 7.62 | 64 140 |
125 | 5 | 124 | 5 | 323 | 12.92 | 255 | 10.20 | 22.3 | 0.89 | 2 | 185.7 | 7.43 | 22.2 | 0.89 | 8 | 215.9 8.64 | 96 212 |
150 | 6 | 149 | 6 | 360 | 14.40 | 280 | 11.20 | 23.9 | 0.96 | 2 | 215.9 | 8.64 | 22.2 | 0.89 | 8 | 241.3 9.65 | 130 285 |
200 | 8 | 190 | 8 | 421 | 16.84 | 315 | 13.80 | 27 | 1.08 | 2 | 269.9 | 10.80 | 22.2 | 0.89 | 8 | 298.5 11.94 | 227 500 |
250 | 10 | 250 | 10 | 450 | 18.00 | 405 | 16.20 | 28.6 | 1.14 | 2 | 323.8 | 12.95 | 25.4 | 1.02 | 12 | 362 14.48 | 355 780 |
300 | 12 | 298 | 81 | 514 | 20.56 | 485 | 19.40 | 30.2 | 1.21 | 2 | 381 | 15.24 | 25.4 | 1.02 | 12 | 431.8 17.27 | 530 1165 |
350 | 14 | 346 | 92 | 672 | 26.88 | 535 | 21.40 | 33.4 | 1.34 | 2 | 412.8 | 16.51 | 28.6 | 1.14 | 12 | 476.3 19.05 | 727 1600 |
400 | 16 | 400 | 102 | 728 | 29.12 | 595 | 23.80 | 35 | 1.40 | 2 | 469.9 | 18.80 | 28.6 | 1.14 | 16 | 539.8 21.59 | 1030 2265 |
450 | 18 | 439 | 114 | 720 | 28.80 | 635 | 25.40 | 38.1 | 1.52 | 2 | 533.4 | 21.34 | 31.75 | 1.27 | 16 | 577.9 23.12 | 1355 2982 |
500 | 20 | 489 | 127 | 790 | 31.60 | 700 | 28.00 | 41.3 | 1.65 | 2 | 584.2 | 23.37 | 31.75 | 1.27 | 20 | 635 25.40 | 1773 3900 |
600 | 24 | 600 | 154 | 967 | 38.68 | 815 | 32.60 | 46.1 | 1.84 | 2 | 692.2 | 27.69 | 34.9 | 1.40 | 20 | 749.3 29.97 | 2818 6200 |
Pressure Regulation Specifications
Nominal Pressure | Shall Test | Sealing Test | Maximum Outlet Pressure |
Regular Range of Outlet |
|||||
Kg/Cm2 | PSI | Kg/Cm2 | PSI | Kg/Cm2 | PSI | Kg/Cm2 | PSI | Kg/Cm2 | PSI |
10 | 14.2 | 11 | 156.5 | 1 | 156.5 | 10 | 142.2 | 0.9-8 | 12.8-113.8 |
16 | 227.6 | 17 | 214.8 | 17 | 241.8 | 16 | 227.6 | 10-14 | 14.2-113.8 |
25 | 335.6 | 27 | 384.0 | 27 | 384.0 | 26 | 355.6 | 1.5-16 | 21.3-227 |